<?xml version="1.0" encoding="utf-8" ?>
<EmbeddedItemColl xsi:type = "Item_CfgColl">
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PTRatioPrimary</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PTRatioSec</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CTRatioPrimary</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CTRatioSec</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/DemandPeriod</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Minutes</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/Dbg</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PulseVal_Whrs</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Wh/VARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ResetReg</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SerialNum</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">0</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_unsigned_long">65535</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalEnergy</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalRealPower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kW</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalReactivePower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAR</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalApparentPower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVA</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgVoltsLN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgVoltsLL</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgCurr</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Amps</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrSystmTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/Freq</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Hz</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SldgWindDmdPwr</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kW</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseBN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseCN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseBC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Volts</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Amps</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Amps</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">Amps</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kW</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kW</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kW</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAR</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAR</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAR</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVA</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVA</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVA</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SoftwareVer</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kWh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVARh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_NUL</UCPTdirection>
		<UCPTunit field = "">kVAh</UCPTunit>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_FLOAT</UCPTbaseType>
		<UCPTmaxFields>0</UCPTmaxFields>
		<UCPTminValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">-3.402823e+38</UCPTminValue>
		<UCPTmaxValue xsi:type = "string" LonFormat = "#8000010128000000[4].UNVT_float">3.402823e+38</UCPTmaxValue>
	</Item>
	<Item xsi:type = "MOD_Device_Cfg">
		<UCPTname>Net/Mod/WattsOn</UCPTname>
		<UCPTannotation>App</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Device_Cfg.htm</UCPTuri>
		<UCPTmaxElements>1</UCPTmaxElements>
	</Item>
	<Item xsi:type = "MOD_Fb_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb</UCPTname>
		<UCPTannotation>VirtualFunctionBlock</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Fb_Cfg.htm</UCPTuri>
		<UCPTfptKey>Virtual Functional Block</UCPTfptKey>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ResetReg</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>135</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalEnergy</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>768</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalRealPower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>770</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalReactivePower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>772</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotalApparentPower</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>774</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgVoltsLN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>776</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgVoltsLL</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>778</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/AvgCurr</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>780</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrSystmTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>782</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/Freq</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>784</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SldgWindDmdPwr</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>786</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>788</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseBN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>790</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseCN</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>792</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>794</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseBC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>796</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/VoltsPhaseAC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>798</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>800</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>802</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CurrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>804</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>806</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>808</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RealPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>810</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>812</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>814</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/RctvPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>816</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>818</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>820</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ApparentPwrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>822</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>824</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>826</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PwrFctrC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>828</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SoftwareVer</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>830</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>832</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>834</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>836</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ImpEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>838</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>840</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>842</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>844</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/ExpEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>846</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>848</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>850</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>852</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotEnrgyABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>854</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>856</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>858</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>860</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/IndEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>862</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>864</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>866</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>868</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CapEnrgyTot</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>870</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>872</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>874</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>876</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVARhABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>878</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhA</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>880</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhB</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>882</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>884</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/TotVAhABC</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_float</UCPTformatDescription>
		<UCPTlength>4</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>886</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>32</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PTRatioPrimary</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>128</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PTRatioSec</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>129</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CTRatioPrimary</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>130</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/CTRatioSec</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>131</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/DemandPeriod</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>132</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/Dbg</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>133</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/PulseVal_Whrs</UCPTname>
		<UCPTannotation>Dp_In</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_IN</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>134</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
	<Item xsi:type = "MOD_Dp_Cfg">
		<UCPTname>Net/Mod/WattsOn/MeterFb/SerialNum</UCPTname>
		<UCPTannotation>Dp_Out</UCPTannotation>
		<UCPThidden>0</UCPThidden>
		<UCPTuri>MOD_Dp_Cfg.htm</UCPTuri>
		<UCPTformatDescription>#8000010128000000[4].UNVT_unsigned_long</UCPTformatDescription>
		<UCPTlength>2</UCPTlength>
		<UCPTdirection xsi:type = "string" LonFormat = "UCPTdirection">DIR_OUT</UCPTdirection>
		<UCPTbaseType xsi:type = "string" LonFormat = "UCPTbaseType">BT_UNSIGNED_LONG</UCPTbaseType>
		<UCPTmodbusTable xsi:type = "string" LonFormat = "UCPTmodbusTable">MTT_HR</UCPTmodbusTable>
		<UCPTstartAddress>149</UCPTstartAddress>
		<UCPTstartBit>0</UCPTstartBit>
		<UCPTbitLength>16</UCPTbitLength>
		<UCPTdataOrdering xsi:type = "string" LonFormat = "UCPTdataOrdering">DO_BIG_ENDIAN</UCPTdataOrdering>
		<UCPTpollRate>60.0</UCPTpollRate>
	</Item>
</EmbeddedItemColl>